The Sick TiM 2D LiDAR sensors offer a high performance for field evaluation and measurement data output in a compact housing.
Scanning ranges go up to 25m and working ranges go up to 270°.
Settings
Property | Default | Description |
---|---|---|
Name | Sick Laser | User-friendly name. |
Enable | ON | Activate to enable the device. |
Run at startup | ON | Activate to enable the device at Kinetic startup. |
IP | 192.168.0 | Enter the IP address of your device. Your device and Kinetic Designer should be on the same subnet. |
Port | 2112 | TCP/IP port used by the device. Do not change unless you know what you are doing. |
Minimum points to create a Cluster | 2 | A cluster is a group of close points which have a position that will be tracked . This setting can help to reduce noise. |
Cluster Expiration Time (ms) | 300 | Time before a cluster is dropped when it is not detected anymore. |
Maximum Clustering Distance (mm) | 50 | Threshold for points close together to be considered as one cluster. |
Tracking Move Threshold (mm) | 2 | Threshold under which movement is not considered movement but eliminated as noise. |
Maximum Matching Distance (mm) | 600 | Threshold over which a cluster can’t be matched as being the same cluster after a movement. |
Minimum Life time (ms) | 0 | Minimum time a cluster must exist before being considered a cluster. This setting can help to reduce noise from reflections. |
Process noise covariance (mm) | 1.0 | Error expected on position evaluation. |
Measure noise covariance (mm) | 4.0 | Error expected on position measurement. |
Positioning Algorithm | Centroid | Method to describe the position of a cluster. ● Centroid: Computes the average of all point coordinates to define the cluster coordinates ● Nearest point: Defines cluster’s position at the coordinates of the cluster’s nearest point to the origin ● Nearest point centroid: Computes an average like centroid but by using the (maximum) 8 nearest points to the origin |
Bounding Box | OFF | Enable bounding box. |
Task action
Action | Description |
---|---|
Enable | Enable the device. |
Disable | Disable the device. |
Start laser | Turn the laser of the device ON. |
Stop laser | Turn the laser of the device OFF. |
Start Record | Start a recording with the device. |
Stop Record | Stop the recording with the device. |
Start Playback | Start a playback of a recording with the device. |
Start Loop Playback | Start a looped playback of a recording with the device. |
Stop Playback | Stop any playback currently playing. |
Task trigger
This device has no actions that can trigger a Task.
Digimap trigger
This device has no actions that can trigger a Digimap.
Graph
Action | Description |
---|---|
Detected Cluster Position | Receive detected clustered points by the device |
User interface
This device has no actions that can be launched from the UI designer.
Device information
Go to the manufacturer website for more information.
Need more help with this?
Don’t hesitate to contact us here.