Choose this device to connect to a PhidgetSpatial Precision 3/3/3 Basic 1042_0B The PhidgetSpatial 3/3/3 combines the functionality of a 3-axis compass, a 3-axis gyroscope, and a 3-axis accelerometer all in one convenient package.

Settings:

Name User-friendly name
Enable Activate to enable the device
Run at startup Activate to run the device at Kinetic startup
Serial Number: Enter the serial number of the VINT HUB Phidget
Port: Choose port number of the VINT HUB Phidget
Data interval ms: Choose the refresh interval in milliseconds

Task action:

N/A

Task trigger:

Trigger a task according to the incoming parameter:

Entry:

Acceleration X select acceleration X as a trigger parameter
Acceleration Y select acceleration Y as a trigger parameter
Acceleration Z select acceleration Z as a trigger parameter
Angular rate X select angular rate X as a trigger parameter
Angular rate Y select angular rate Y as a trigger parameter
Angular rate Z select angular rate Z as a trigger parameter
Magnetic field X select magnetic field X as a trigger parameter
Magnetic field Y select magnetic field Y as a trigger parameter
Magnetic field Z select magnetic field Z as a trigger parameter
Orientation X select orientation X as a trigger parameter
Orientation Y select orientation Y as a trigger parameter
Orientation Z select orientation Z as a trigger parameter

Condition:

greater than trigger the task when the incoming value is superior to the condition value
less than trigger the task when the incoming value inferior,to the condition value
greater than or equal to trigger the task when the incoming value is superior or equal to the condition value
less than or equal trigger the task when the incoming value is inferior or equal to the condition value
eguals trigger the task when the incoming value is equal to the condition value
range trigger the task when the incoming value is superior to the condition value min and inferior to value max

Value:
Set the condition value

Hysteresis:
For all theses conditions, you can set a hysterys value to avoid false triggering.
For example you use the > condition with a value of 0.5, you set an hysterys value of 0.1. When the incoming value reach 0.5, the task is triggered.
If the incoming value go back to 0.45 then go to 0.5, the task is not triggered.
If the incoming value go back to 0.35 (less than condition value – hystererys value) then go to 0.5, the task is triggered.

Digimap trigger:

Use the acceleration, angular rate, magnetic field and orientation in X,Y or Z axis as input for digimap.

Graph:

value get acceleration, angular rate, magnetic field and orientation

User interface:

You can add this device in any user panel.
You can then choose the available features in the panel.

Device information:

Go to this page for more information.
You need to plug this device to a VINT HUB Phidget.

Need more help with this?
Don’t hesitate to contact us here.

Thanks for your feedback.