Choose this device to monitor a temperature/humidity sensor Papago 2TH

Settings:

Name User-friendly name
Enable Activate to enable the device
Run at startup Activate to run the device at Kinetic startup
IP set the device IP adress; Your device and Kinetic Designer need to be in the same subnet

Monitor directly the temperature and humidity in this panel.

Task action:

N/A

Task trigger:

Trigger a task according to the incoming parameter:

Condition:

greater than trigger the task when the incoming value is superior to the condition value
less than trigger the task when the incoming value inferior,to the condition value
greater than or equal to trigger the task when the incoming value is superior or equal to the condition value
less than or equal trigger the task when the incoming value is inferior or equal to the condition value
eguals trigger the task when the incoming value is equal to the condition value
range trigger the task when the incoming value is superior to the condition value min and inferior to value max

Value:
Set the condition value

Hysteresis:
For all theses conditions, you can set a hysterys value to avoid false triggering.
For example you use the > condition with a value of 0.5, you set an hysterys value of 0.1. When the incoming value reach 0.5, the task is triggered.
If the incoming value go back to 0.45 then go to 0.5, the task is not triggered.
If the incoming value go back to 0.35 (less than condition value – hystererys value) then go to 0.5, the task is triggered.

Digimap trigger:

N/A

User interface:

You can add this device in any user panel.
You can then choose the available features in the panel.

Graph:

N/A

Device information: